  1. Projection Room - The Building Code Forum

    Jul 24, 2019 · A projector is a type of theatrical lighting, is it not On the other hand, if this projector is in a conventional room with a path of travel via conventional stairs, hallways, and doorways, and this is …

  2. Flexible Cords Above Drop Ceiling - The Building Code Forum

    Oct 16, 2009 · Are flexible power cords for items such as conference room projectors, televisions, etc. etc. prohibited from being used above drop ceilings? Are those power cords listed in a different …

  3. AFCI protection - Mechanical rooms | The Building Code Forum

    Oct 19, 2021 · When does a mechanical room qualify as a closet or similar room/area and need AFCI protection on the 120v outlets? Does it ever? Which, if any, of the following would you make …

  4. Furnace / Boiler Room - The Building Code Forum

    Oct 12, 2010 · 2009 IBC / IMC Where does the code dictate when an enclosed room is required for a furnace or a boiler? I know IBC Table 508.2.5 says a furnace room where any piece of equipment is …

  5. locker room occupancy - The Building Code Forum

    Jul 15, 2024 · I'm calculating the occupancy a locker room as part of a school project. The locker room is 620 square feet and contains 50 lockers. do i use "locker room" use per table 1004.5 which uses 50 …

  6. Unisex Toilet Rooms and Locations: ADA Explained

    Oct 16, 2009 · In accordance with accessibility standards, accessible unisex toilet rooms cannot replace multi-user toilet rooms, except in cases where it is not technically feasible to make multi-user rooms …

  7. Fire rating of electrical equipment rooms - The Building Code Forum

    Dec 17, 2010 · 2. Any room or space where sprinklers are considered undesirable because of the nature of the contents, when approved by the fire code official. 3. Generator and transformer rooms …

  8. Fire Riser Rooms - The Building Code Forum

    Oct 25, 2010 · room / space will have the fire sprinkler riser, associated valves, controls, etc. The RDP's have not included the lighting, heating and electrical receptacle for this room / space in their design, …

  9. NFPA 101 Business Occupancy storage room protection

    Apr 19, 2016 · The Business storage room protection requirements in the NFPA appear to be much more stringent than the IBC (no rated protection required for accessory storage under 100 SF), but …

  10. Assembly Means of Egress | The Building Code Forum

    Oct 30, 2009 · A room or space used for assembly purposes that contains seats, tables, displays, equipment or other material shall comply with this section. Is this chapter applicable to a lounge / …